R1 hose is suitable for hydraulic fluids on mineral oil and synthetic oil basis (HL, HLP, HLPD, HVLP), oil-water-emulsions (HFAE, HFAS, HFB), water-glycol liquids (HFC), vegetable and mineral oil based lubricants, cooling water, and compressed air. Also generally suitable for biologically degradable hydraulic liquids (HETG, HEPG, HEES) however limited by fluid additives.
Not suitable for hydraulic fluids on phosphate ester basis (HFD).
Use this hose with:
Untitled Document
Hose
Number |
Inside
Diameter |
Outside
Diameter |
Maximum Working
Pressure (MWP) |
Minimum
Burst Pressure |
Minimum
Bend Radius |
R1-04 |
1/4" |
0.53" |
2,750 psi |
11,000 psi |
4" |
R1-06 |
3/8" |
0.69" |
2,250 psi
|
9,000 psi |
5" |
R1-08 |
1/2" |
0.82" |
2,000 psi |
8,000 psi |
7" |
R1-10 |
5/8" |
0.94" |
1,500 psi |
6,000 psi |
8" |
R1-12 |
3/4" |
1.10" |
1,250 psi |
5,000 psi |
9.5" |
R1-16 |
1" |
1.41" |
1,000 psi |
4,000 psi |
12" |
Tube: |
Oil-resistant synthetic rubber |
Reinforcement: |
One braid of high-tinsile steel wire |
Cover: |
Oil and Abrasion-resistant synthetic rubber |
Temperature: |
-40°F to +212°F |
Use the below table to determine hose protection options for your hydraulic hose
Hose
Number
|
Outside Diameter
|
Plastic Spiral Guard (NFSGX)
|
Nylon Protective Sleeving (NPS)
|
Steel Hose Armor (HA)
|
Fire Resistant Sleeving
|
R1-04
|
0.53"
|
NFSGX16
|
NPS-076
|
HA-13S
|
1310-08
|
R1-06
|
0.69"
|
NFSGX25
|
NPS-076
|
HA-3S
|
1910-12
|
R1-08
|
0.82"
|
NFSGX25
|
NPS-105
|
HA-4S
|
2210-14
|
R1-10
|
0.94"
|
NFSGX32
|
NPS-105
|
HA-5S
|
2510-16
|
R1-12
|
1.10"
|
NFSGX32
|
NPS-122
|
HA-14S
|
3210-20
|
R1-16
|
1.41"
|
NFSGX40
|
NPS-153
|
HA-9S
|
3810-24
|
This hose is suitable for hydraulic fluids on mineral oil and synthetic oil basis (HL, HLP, HLPD, HVLP), oil-water-emulsions (HFAE, HFAS, HFB), water-glycol liquids (HFC), vegetable and mineral oil based lubricants, cooling water, and compressed air. Also generally suitable for biologically degradable hydraulic liquids (HETG, HEPG, HEES) however limited by fluid additives.
Not suitable for hydraulic fluids on phosphate ester basis (HFD).
A Word About Hose Orientation...
To help assist you with hose orientation questions please refer to the graphic below. When selecting a hose with multiple angled fittings, simply let us know how to orient the fittings in the Order Notes field at checkout. If you have any questions, you can always use live chat, or call us with any questions!
|
|
 |